Backup-line protection panel Single-phase 10 kW

€ 441.65 (VAT included)

In stock

Modular sub-panel for the critical-loads (EPS) line: 40 A 1P+N breaker, 30 mA type-A RCD, type-II AC SPD and quick-connect terminals for the hybrid inverter backup output. Sized for up to 10 kW. Includes a DIN-rail Auto Transfer Switch (ATS) – 2P/4P 40-63-100Amps: in a blackout it moves the critical-load line to the inverter's EPS output with no manual switching.

Specifications

PhasesSingle-phase
SubcategoryPanels & boxes
TypeElectrical panel
UseElectrical panel
Poles1P+N
IP ratingIP65
Rated current40 Amps
Voltage230 Volts
Curva de disparoC
Conmutador ATS2P/4P 40-63-100 A

FAQ

Which hybrid inverters is this protection panel compatible with?

The panel is designed for single-phase hybrid inverters and connects via quick-terminal wiring to the inverter's backup (EPS) output. It is compatible with any single-phase hybrid inverter whose backup line does not exceed 10 kW.

Does the panel switch to the battery by itself in a blackout?

Yes. It comes with an Auto Transfer Switch (ATS) – 2P/4P 40-63-100Amps fitted: when the grid drops it moves the critical-load line to the inverter's EPS output, and back to the grid when power returns — no manual switching.

Is this product enough for a 8kW solar system?

Yes, the panel is rated for systems up to 10 kW, so a 8 kW installation is well within its capacity. The built-in 40 A 1P+N circuit breaker supports that load on a single-phase supply.

What protections are included out of the box?

The panel includes a 40 A 1P+N MCB, a 30 mA Type A RCD and a Type II AC surge protective device (SPD). Together they protect against overcurrent, earth leakage and voltage transients from the grid.

Why is a Type A RCD required instead of a standard Type AC?

Type A RCDs detect both alternating and pulsating DC residual currents, which are common in installations with inverters and electronic loads. This makes them the correct choice under current electrical standards for PV and hybrid systems.

What is included in the box when the order arrives?

The panel arrives fully assembled with the 100 A 1P+N MCB, 30 mA Type A RCD, Type II AC SPD and terminals ready for inverter connection. No additional protection components are needed for the backup line.

Does this panel need to be installed by a certified electrician?

Yes, installation must be carried out by a qualified electrician in accordance with applicable low-voltage electrical regulations. This is mandatory for any AC protection panel operating at this power level.